  Datasheet File OCR Text:
  mpu150/mdu150 series data sheet mcd10009 rev. 1.0, 15-oct-07 page 1 of 6 www.power-one.com the innovative mpu products incorporate power factor correction (pfc) with a low-profile package designed to meet 1u height constraints. the mpu150-4530 and mpu150-4350 provide high current +3.3v and +5v on a single platform to support mixed-mode, high-speed digital circuitry. power-one?s unique dual converter architecture combines high reliability with exceptional regulation. all multiple output models feature remote sense on outputs v1 and v2 to provide independent compensation of output cable losses. other standard features include independent current sharing on v1 and v2, thermal shutdown, and remote inhibit. airflow of 300 linear feet per minute (lfm) is required to deliver the full power density of 3.0 watts per cubic inch. the mdu150 series provides the same benefits as the mpu150 series, with nominal 48 volt dc input. description features ? rohs lead free solder and lead solder exempted products are available ? power factor correction (pfc) meets en61000-3-2 ? low-profile height fits 1u constraints ? dual main outputs provide 3.3v and 5v for mixed mode applications ? single wire current sense on outputs v1 and v2 ? remote sense on outputs v1 and v2 ? overtemperature, overload, and overvoltage protection ? available with metric or sae mountings ? greater than 340,000 hours mtbf ? mdu150 models have 48vdc input model numbers highlighted in yellow or shaded are not recommended for new designs. see mpu200 for new designs. ac input, single output model selection - 180w with 300 lfm forced-air cooling model output adjustment maximum output line load ripple & noise initial setting voltage range current (note 1) regulation regulation %p-p (note 2) accuracy mpu150-s259 12v 11.6v to 16v 15a (note 3) 0.1% 1% 1% 11.97v to 12.03v mpu150-s262 24v 22.8v to 29.2v 7.5a (note 3) 0.1% 1% 1% 23.95v to 24.05v mpu150-s261 48v 45v to 56v 3.75a (note 3) 0.1% 1% 1% 47.9v to 48.1v ac input, multiple output model selection - 150w with 300 lfm forced-air cooling isolated v3 and v4 can be used as positive or negative outputs model output adjustment output line load ripple & noise initial setting voltage range current (note 1) regulation regulation %pk-pk (note 2) accuracy +3.3v 3.15v to 3.80v 35a 0.6% 1.5% 1.5% 3.28v to 3.32v mpu150-3300 +5v 5.0v to 5.5v 20a 0.4% 3% 1% 4.98v to 5.02v +12v fixed 2a 0.4% 3% 1% 11.76v to 12.24v +5v 5.0v to 5.5v 17.5a 0.4% 1% 1% 4.98v to 5.02v mpu150-3524 +12v 10.8v to 13.2v 4a 0.4% 3% 1% 11.94v to 12.06v +24v fixed 2a 0.4% 3% 1% 23.52v to 24.48v +5v 5.0v to 5.5v 30a (note 4) 0.4% 1% 1% 4.98v to 5.02v mpu150-4000 +12v 10.8v to 13.2v 8a 0.4% 1% 1% 11.94v to 12.06v 12v 10.8v to 13.2v 3a 0.4% 1% 1% 11.94v to 12.06v 5v 5.0v to 5.5v 2a 0.4% 1% 1% 4.98v to 5.02v +2.5v 2.25v to 3.0v 30a (note 4) 0.8% 2% 2% 2.49v to 2.51v mpu150-4230 +3.3v 3.15v to 3.8v 15a (note 4) 0.6% 1.5% 1.5% 3.28v to 3.32v 12v 10.8v to 13.2v 4a (note 5) 0.4% 1% 1% 11.94v to 12.06v 5v 5.0v to 5.5v 2a (note 5) 0.4% 1% 1% 4.98v to 5.0v +3.3v 3.15v to 3.80v 30a (note 4) 0.6% 1.5% 1% 3.28v to 3.32v mpu150-4350 +5v 5.0v to 5.5v 15a (note 4) 0.4% 1% 1% 5.00v to 5.04v 12v 10.8v to 13.2v 3a (note 5) 0.4% 7% 1% 11.94v to 12.06v 12v 10.8v to 13.2v 3a (note 5) 0.4% 7% 1% 11.94v to 12.06v +5v 5.0v to 5.5v 30a (note 4) 0.4% 1% 1% 4.98v to 5.02v mpu150-4530 +3.3v 3.15v to 3.60v 15a (note 4) 0.6% 1.5% 1.5% 3.28v to 3.32v 12v 10.8v to 13.2v 3a (note 5) 0.4% 7% 1% 11.94v to 12.06v 12v 10.8v to 13.2v 3a (note 5) 0.4% 7% 1% 11.94v to 12.06v notes: 1) the mpu/mdu150 products require a minimum of 300 lfm of forced-air cooling under 4) total current between v1 and v2 is 30a, maximum rating. all load conditions. it is recommended that the airflow be applied from the input side of the 5) total current between v3 and v4 is 5a, maximum rating. power supply blowing towards the output . 2) maximum peak-to-peak noise expressed as a percentage of output voltage, 20 mhz bandwidth. 3) total power of 180 watts.
mpu150/mdu150 series data sheet mcd10009 rev. 1.0, 15-oct-07 page 2 of 6 www.power-one.com ordering information: options suffixes to add to part number metric mounting add ?m? as a suffix to the model number to order chassis with m4 x 0.7 mounting inserts. metric mounting inserts are standard for single-output models mpu150-s259, mpu150-s261, and mpu150-s262. rohs lead solder exemption no rohs suffix character required. rohs compliant for all 6 substances add ?g? as the last character of the part number. dc input model selection - 150w with 300 lfm forced-air cooling isolated v3 and v4 can be used as positive or negative outputs model output adjustment output line load ripple & noise initial setting voltage range current (note 1) regulation regulation %pk-pk (note 2) accuracy +3.3v 3.15v to 3.80v 35a 0.6% 1.5% 1.5% 3.28v to 3.32v mdu150-3300 +5v 5.0v to 5.5v 20a 0.4% 3% 1% 4.98v to 5.02v +12v n/a 2a 0.4% 3% 1% 11.76v to 12.24v +5v 5.0v to 5.5v 30a (note 3) 0.4% 1% 1% 4.98v to 5.02v mdu150-4000 +12v 10.8v to 13.2v 8a 0.4% 1% 1% 11.94v to 12.06v 12v 10.8v to 13.2v 3a 0.4% 1% 1% 11.94v to 12.06v 5v 5.0v to 5.5v 2a 0.4% 1% 1% 4.98v to 5.02v +2.5v 2.25v to 3.0v 30a (note 3) 2% 2% 2% 2.49v to 2.51v mdu150-4230 +3.3v 3.15v to 3.8v 15a (note 3) 1.5% 1.5% 1.5% 3.28v to 3.32v 12v 10.8v to 13.2v 3a 1% 1% 1% 11.94v to 12.06v 5v 5.0v to 5.5 v 2a 1% 1% 1% 4.98v to 5.0v +3.3v 3.15v to 3.8v 30a (note 5) 1.5% 1.5% 1% 3.28v to 3.32v mdu150-4350 +5v 5.0v to 5.5v 15a (note 5) 1% 1% 1% 5.00v to 5.04v 12v 10.8v to 13.2v 3a (note 4) 7% 7% 1% 11.94v to 12.06v 12v 10.8v to 13.2v 3a (note 4) 7% 7% 1% 11.94v to 12.06v +5v 5.0v to 5.5v 30a (note 3) 0.4% 1% 1% 4.98v to 5.02v mdu150-4530 +3.3v 3.15v to 3.60v 15a (note 3) 0.6% 1.5% 1.5% 3.28v to 3.32v 12v 10.8v to 13.2v 3a (note 4) 0.4% 7% 1% 11.94v to 12.06v 12v 10.8v to 13.2v 3a (note 4) 0.4% 7% 1% 11.94v to 12.06v notes: 1) the mpu/mdu150 products require a minimum of 300 lfm of forced-air cooling 4) total current between v3 and v4 is 5a, maximum rating. under all load conditions. it is recommended that the airflow be applied from the 5) total current between v1 and v2 is 40a, maximum rating input side of the power supply blowing towards the output . 2) maximum peak-to-peak noise expressed as a percentage of output voltage, 20 mhz bandwidth. 3) total current between v1 and v2 is 30a, maximum rating. mpu150 input specifications parameter conditions/description min nom max units input voltage - ac continuous input range. 85 264 vac input frequency ac input. 47 63 hz hold-up time after last ac line peak at 150 watts. mpu150-4350 17.5 ms all other models 20 input current 85 vac at full rated load. mpu150 3.0 a rms input protection non-user serviceable internally located ac input line fuse. inrush surge current internally limited by thermistor. vin = 230 vac, one cycle, 25c. 35 a pk power factor per en61000-3-2. 0.95 w/va operating frequency switching frequency of main output transformer. 100 120 switching frequency of secondary transformer. 65 90 khz switching frequency of power factor correction circuit. 60
mdu150 input specifications parameter conditions/description min nom max units input voltage - dc continuous input range. 36 75 vdc brown out protection lowest dc input voltage that regulation is maintained with full rated loads. 34 vdc hold-up time at 150 watts, over dc input range. 20 ms input current 36 vdc at full rated load. 6.4 a rms input protection non-user serviceable internally located ac input line fuse. operating frequency switching frequency of main output transformer. 100 khz switching frequency of secondary transformer. 70 inrush current consult factory. output specifications parameter conditions/description min nom max units efficiency full rated load, 110 vac. varies with distribution of loads among outputs. 65 75 % minimum load, v1 minimum load required to maintain regulation on, triple output models v1 4 a v2 at maximum load. quad output models v1 3 minimum load required on single output models. single output models v1 0 minimum load, v3 minimum load required to maintain regulation on quad output models v3 0.3 a v4 at maximum load. triple output models v3 0 ripple and noise full load, 20 mhz bandwidth. see model selection charts output power with 300 lfm forced air cooling. (note 1) 150 watts overshoot / undershoot output voltage overshoot/undershoot at turn-on. 0 3 5 % regulation varies by output. total regulation includes: line changes over the specified. see model selection charts input range, changes in load starting at 20% load and changing to 100% load. transient response recovery time, to within 1% of initial set point due to a 50-100% load change, 500 s 5% max. deviation. turn-on delay time required for initial output voltage stabilization. 2 s turn-on rise time time required for output voltage to rise from 10% to 90%. 50 ms notes: 1) this product is not rated for convection applications. interface signals and internal protection parameter conditions/description min nom max units overvoltage protection latch style overvoltage protection. available on 2.5v output, v1 3.0 3.25 v1, v2, all models, and v3 on all models except 3.3v output, v1 4.1 4.65 mpu150-3300. 3.3v output, v2 3.8 4.2 5v output, v1, v2 6.0 6.4 12v output, v2 14 16 v 12v output, v3 14 19 mpu150-4350g 3.3v output, v1 4.3 4.65 mpu150-s259 v1 17.0 20.5 mpu150-s262 v1 32.0 38.0 mpu150-s261 v1 58.0 62.7 overload protection fully protected against output overload and short circuit. automatic recovery upon removal of overload cond ition. overtemperature protection system shutdown due to excessive internal temperature, automatic reset. output good signal, ttl compatible signal available for v1. pull-up resistor is 10k  . signal 3.3v 3.16 3.25 low to high transition is high when output is above the specified limits. signal shall remain low 5v 4.75 4.90 for 20 milliseconds following loss of output good. mpu150-s259 12v 10.5 11.9 v mpu150-s262 24v 21.5 23.5 mpu150-s261 48v 43.0 47.0 input power fail warning ttl compatible logic signal. time before regulation dropout due to loss of input 5ms power. may be used as independent psok signal in redundant applications. current share accuracy of shared current with up to 6 parallel units. single wire current share 10 % on v1 and v2 with return via -sense return. remote sense available on v1 and v2. total voltage compensation for cable losses with 500 mv respect to the main output. inhibit output voltage is inhibited by application of an external high (5v) signal. mpu150/mdu150 series data sheet mcd10009 rev. 1.0, 15-oct-07 page 3 of 6 www.power-one.com
safety, regulatory, and emi specifications parameter conditions/description min nom max units agency approvals ul1950. csa 22.2 no. 234/950. approved en60950 (tv). dielectric withstand voltage input to output per en60950. mpu150 2600 vdc mdu150 1544 electromagnetic interference fcc cfr title 47 part 15 sub-part b - conducted. b class en55022 / cispr 22 conducted. b esd susceptibility per en61000-4-2, level 4. 8 kv radiated susceptibility per en61000-4-3, level 3. 10 v/m eft/burst per en61000-4-4, level 3. 2 kv input transient protection per en61000-4-5, class 3. mpu150: line to line 1 kv mpu150: line to ground 2 mdu150: line to line 0.5 mdu150: line to ground 0.5 insulation resistance input to output. 10 m  leakage current per en60950. dual output mpu150 at 264 vac 22 single and triple output mpu150 at 264 vac 1.7 ma mdu150 at 72 vdc (not required by en60950) environmental specifications parameter conditions/description min nom max units altitude operating. 10k asl ft. non-operating. 40k asl ft. operating temperature at 100% load 0 50 c derate linearly above 50c by 2.5% per c. at 50% load 0 70 c storage temperature -55 85 c temperature coefficient 0c to 70c (after 15 minute warm-up). 0.02 0.05 %/c relative humidity non-condensing. 5 95 %rh shock peak acceleration. 20 g pk vibration random vibration, 10hz to 2khz, 3 axis. 6 g rms options description notes size impact metric mounting add ?m? as a suffix to the model number to order chassis with 8.00" x 4.20" x 1.50" m4 x 0.7 mounting inserts. metric mounting inserts are standard for (203.2mm x 106.7mm x 38.1mm) single-output models mpu150-s259, mpu150-s261, and mpu150-s262. mpu150/mdu150 series data sheet mcd10009 rev. 1.0, 15-oct-07 page 4 of 6 www.power-one.com nuclear and medical applications - power-one products are not designed, intended for use in, or authorized for use as critical c omponents in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written conse nt of the respective divisional president of power-one, inc. technical revisions - the appearance of products, including safety agency certifications pictured on labels, may change dependin g on the date manufactured. specifications are subject to change without notice.
chassis: 0.063" (1.6mm) aluminum alloy, with clear finish overall size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) weight: 1.8 lb (0.82 kg) (4pl) connections 8-32 screw outputs: input s adj. v1,v. n l +v1 j1 rtn pins series 5263, p/n: 80-70-1040 (loose) housing series 5264-n, p/n: 50-37-5103 (&) mates with molex: on 2.50mm centers. molex series 5268-na, p/n: 22-05-7105, pins 1. signal ground 2. inhibit 3. power fail warning 4. output good, v1 5. no connection 6. no connection 7. no connection 8. current share, v1 9. -s, v1 10. +s, v1 pin interface connections (j300) single output m4 x 0.7, 8 places. maximum torque: 3.5 in/lbs (0.40 n/m) note: max. lead protrusion is 0.0625" (1.588mm) on the four bottom mounting holes. max. lead protrusion of 0.25" (6.25mm) is acceptable on the four side mounting holes. connector molex housing pin pins pins wire series series (loose) (chain) gauge 41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20awg j1 41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20awg (all models) 2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20awg j300 5264-n 50-37-5103 5263 08-70-1040 08-70-1039 22-28awg mpu150/mdu150 series data sheet mcd10009 rev. 1.0, 15-oct-07 page 5 of 6 www.power-one.com
connector molex housing pin pins pins wire series series (loose) (chain) gauge 41695 09-50-8051 6838 08-50-0189 08-50-0187 18-20awg j1 41695 09-50-8051 2478 08-50-0106 08-50-0105 18-20awg (all models) 2139 09-50-3051 2478 08-50-0106 08-50-0105 18-20awg j2 5051-n 22-01-1022 2759 08-50-0114 08-50-0113 22-30awg (triple output) 5051-n 22-01-1022 2759 08-65-0805 08-65-0804 22-30awg 41695 09-50-8021 6838 08-50-0189 08-50-0187 18-20awg j3 41695 09-50-8021 2478 08-50-0106 08-50-0105 18-20awg (triple output) 2139 09-50-3021 2478 08-50-0106 08-50-0105 18-20awg 41695 09-50-8061 6838 08-50-0189 08-50-0187 18-20awg j3 41695 09-50-8061 2478 08-50-0106 08-50-0105 18-20awg (quad output) 2139 09-50-3061 2478 08-50-0106 08-50-0105 18-20awg j300 5264-n 50-37-5103 5263 08-70-1040 08-70-1039 22-28awg overall size: 8.00" x 4.20" x 1.50" (203.2mm x 106.7mm x 38.1mm) weight: 2.0 lb (0.89 kg) note: max. lead protrusion is 0.0625" (1.588mm) on the four bottom mounting holes. max. lead protrusion of 0.25" (6.25mm) is acceptable on the four side mounting holes. chassis: 0.063" (1.6mm) aluminum alloy, with clear finish mpu150/mdu150 series data sheet mcd10009 rev. 1.0, 15-oct-07 page 6 of 6 www.power-one.com


▲Up To Search▲   

 
Price & Availability of MPU150-4000MG

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X